PRODUCT

IUXPOWER Electronic Technolohy Co;Ltd

Product

CRIK5000 DC ELECTRONIC LOAD
+
  • CRIK5000 DC ELECTRONIC LOAD

CRIK5000 DC ELECTRONIC LOAD

The CIRK5000 series of high-power programmable DC electronic loads is a high-reliability, high-precision, and cost-effective full-featured DC electronic load product.
The entire CIRK5000 series of loads is ahead of similar products in terms of reliability, maintainability, scalability, and security, and continues to develop.

Product Inquiry
Image Name

Details

  Product Features


◆ Power range covers 1-500KW, meeting the needs of various industries.

◆ Voltage range of 120V, 600V, 1000V three specifications, other levels can be customized.

◆ Complete protection functions, overcurrent, overvoltage, overtemperature, overpower and reverse polarity reminder protection; all-round MOS protection to avoid blowing the machine.

◆ Multiple load cascading, power can be easily expanded at any time.

◆ Distributed design, power expansion and maintenance are extremely convenient.

◆ High power density, saving valuable space.

◆ Four test modes: constant current (CC), constant voltage (CV), constant resistance (CR), and constant power (CP).

◆ Load and unload voltage is programmable, reducing unexpected events during testing and measurement.

◆ Pure hardware constant resistance and constant power design, stable and reliable.

◆ Simulated short circuit function.

◆ Powerful charge and discharge control function, can be connected in series for charge and discharge, convenient for battery and supercapacitor testing.

◆ Built-in ESR test function, supports various industry standards, battery and supercapacitor users can save valuable investment.

◆ Convenient and practical OCP test.

◆ Up to 20KHz dynamic test performance, rise and fall slopes can be set separately.

◆ Large-size color LCD screen, more comprehensive information display.

◆ Intelligent fan control, low noise, more environmentally friendly.

◆ Powerful automatic test function, complex test tasks can be completed with one click.

◆ Analog programming interface, current monitoring interface, remote and local trigger function, can realize complex function control and monitoring.

◆ Multiple communication control interfaces, LAN, RS232, CAN, GPIB (optional).

◆ 3U standard 19-inch module, convenient for rack applications.

◆ Unparalleled high reliability, leading the industry in mean time between failures.

 

  Product Characteristics


The load design has all-round MOS protection, and fuses are designed around the MOS. No matter how the MOS is damaged, it will not cause a short circuit between the positive and negative poles or between the positive pole and the control circuit. Partial MOS damage will not accelerate the damage of other MOS, and can be used continuously.

Distributed design, power layers can be directly replaced or added, maintenance is simple and convenient, and power expansion is easy.

A power limiting circuit is designed, with a very short response time, which can effectively protect the load from damage due to overpower.

Full shielding technology is adopted, whether it is internal or external wiring or PCB wiring, shielding technology is adopted, and digital communication is used between layers, which effectively improves the anti-interference ability of the load.


  Special Features:


Constant Current Test Function (CC)

In constant current mode, regardless of the input voltage changes, the load always consumes a constant current.

Constant Voltage Test Function (CV)

In constant voltage mode, the load will consume enough current to maintain the input voltage at the set value.

Constant Resistance Test Function (CR)

In constant resistance mode, the load is equivalent to a constant resistor, and the input current will adjust with the change of the input voltage.

Constant Power Test Function (CP)

In constant power mode, the load will consume a constant power. The input current will linearly adjust with the change of the input voltage to ensure that the power consumption remains unchanged.

Dynamic Current Test Function (CCD)

The dynamic test function can switch the load between two set parameters (main value and transient value) according to the set rules, suitable for power dynamic characteristic testing. Press the panel button "CCD" to quickly switch to the dynamic test interface, and after setting the parameters, use the button "On/Off" to turn the dynamic test function on or off.

Test interface, set parameters, then use the button "On/Off" to turn the dynamic test function on or off.

Automatic Test Function (Auto)

The automatic test function is used to simulate real load waveforms and provide an efficient specification checking process, which can significantly improve testing efficiency. This function allows users to edit 4 sequence test files, each test file can

support 50 test steps. In each test step, the user can set the load mode, load main value, rise slope, fall slope, single-step time, and check content.

Discharge Test Function (Discharge)

The discharge test function is used to perform discharge tests on batteries or supercapacitors. During the test, the voltage of the battery (or capacitor) continuously decreases, and when the voltage is lower than the termination voltage, the load closes the input and stops discharging.

Charging Test Function (Charge)

In addition to providing constant current charging, the CIRK5000 series load also adds an intelligent constant current to constant voltage charging mode to meet customer's charging quality requirements (as full as possible). The charging test function requires series

power supply and battery (or supercapacitor), and use a remote voltage sampling cable.

Equivalent DC Internal Resistance Test Function (ESR)

The CIRK5000's professional internal resistance sampling circuit can accurately capture the voltage drop of the device under test. According to Ohm's law, the equivalent DC internal resistance can be calculated.

Overcurrent Protection Test Function (OCP)

The load provides a rising ramp current to test whether the voltage of the device under test can reach the termination potential, to determine whether the OCP protection is normal. This test checks the output response of the device under test under overload conditions.


  Typical Application Areas:


◆ Charging piles, power batteries, fuel cells

◆ Power tools, BMS protection boards

Communication power supplies, electric power supplies, locomotive power supplies

Supercapacitors (modules, protection boards)

Generators, electric motors

Solar energy and related components

Current devices (relays, fuses, electrical connectors, sensors, etc.)

Aerospace

Power supply testing

Electric vehicles, hybrid vehicles

Power electronics industry

Green energy, including electricity storage

 

 

  Product Specifications


CRIK5000 DC Electronic Load
ModelCRIK5003-120-300CRIK5003-600-90CRIK5003-1000-30CRIK5012-120-1200
Voltage120V600V1,000V120V
Current300A90A30A1200A
Power3,000W3,000W3,000W12,000W
Minimum Operating Voltage2V/300A4.5V/90A5V/30A2V/1200A
Constant Current Mode
Range0-30A0-300A0-9A0-90A0-3A0-30A0-120A0-1200A
Resolution0.5mA5mA0.15mA1.5mA0.05mA0.5mA2mA20mA
AccuracyLow range accuracy: 0.1%+0.1%F.S.; High range accuracy: 0.1%+0.15%F.S.
Constant Voltage Mode
Range0-12V0-120V0-60V0-600V0-100V0-1000V0-12V0-120V
Resolution0.2mV2mV1mV10mV1.67mV16.7mV0.2mV2mV
Accuracy0.05%+0.1%F.S.
Constant Power Mode
Range0-3,000W0-3,000W0-3,000W0-12,000W
Resolution50mW50mW50mW200mW
Accuracy0.5%+1%F.S.
Constant Resistance Mode
Range0.007~74Ω0.15~1200Ω0.12~1240Ω2.5~20000Ω0.62~6200Ω12.4~100000Ω0.0019~19Ω0.037~300Ω
Accuracy0.35%+0.42S0.35%+0.0026S0.35%+0.0252S0.35%+157u S0.35%+0.005S0.1%+31uS0.35%+1.68S0.35%+0.01S
Resolution16  bits
Slope
Current Slope Range5-300A/ms300-15000A/ms1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms20-1200A/ms1200-60000A/ms
Voltage Slope Range1.0-50V/ms50-500V/ms5.0-250V/ms250-2500V/ms8-400V/ms400-4000V/ms1.0-50V/ms50-500V/ms
Power Slope Range5-300A/ms300-15000A/ms1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms20-1200A/ms1200-60000A/ms
Resistance Slope Range5-300A/ms300-15000A/ms1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms20-1200A/ms1200-60000A/ms
Accuracy(1±35%)*Set Value
Voltage Measurement
Range0-12V0-120V0-60V0-600V0-100V0-1000V0-12V0-120V
Accuracy0.05%+0.05%F.S.0.05%+0.05%F.S.0.05%+0.05%F.S.0.05%+0.05%F.S.
Current Measurement
Range0-30A0-300A0-9A0-90A0-3A0-30A0-120A0-1200A
Accuracy0.1%+0.1%F.S.0.1%+0.1%F.S.0.1%+0.1%F.S.0.1%+0.1%F.S.
Power Measurement
Range0-3,000W0-3,000W0-3,000W0-12,000W
Accuracy0.5%+1%F.S.0.5%+1%F.S.0.5%+1%F.S.0.5%+1%F.S.
Transient Measurement
T1&T20.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms
Resolution1us1ms1us1ms1us1ms1us1ms
Accuracy1us+100ppm1ms+100ppm1us+100ppm1ms+100ppm1us+100ppm1ms+100ppm1us+100ppm1ms+100ppm
Dimensions13cm(H)×48cm(W)×64cm(D)52cm(H)×48cm(W)×64cm(D)
Temperature SpecificationsProtection temperature 85°C, operating temperature 0 ~40 °C, full power operating temperature 0 ~25 °C

See table below:

ModelCRIK5012-600-360CRIK5012-1000-120CRIK5021-600-630CRIK5021-1000-210
Voltage600V1,000V600V1,000V
Current360A120A630A210A
Power12,000W12,000W21,000W21,000W
Minimum Operating Voltage4.5V/360A5V/120A4.5V/630A5V/210A
Constant Current Mode
Range0-36A0-360A0-12A0-120A0-63A0-630A0-21A0-210A
Resolution0.6mA6mA0.2mA2mA1.05mA10.5mA0.3mA3mA
AccuracyLow range accuracy: 0.1%+0.1%F.S.; High range accuracy: 0.1%+0.15%F.S.
Constant Voltage Mode
Range0-60V0-600V0-100V0-1000V0-60V0-600V0-100V0-1000V
Resolution1mV10mV1.67mV16.7mV1mV10mV1.67mV16.7mV
Accuracy0.05%+0.1%F.S.
Constant Power Mode
Range0-12,000W0-12,000W0-21,000W0-21,000W
Resolution200mW200mW350mW350mW
Accuracy0.5%+1%F.S.
Constant Resistance Mode
Range0.03~300Ω0.62~5000Ω0.15~1500Ω3~25000Ω0.018~180Ω0.35~2800Ω0.09~880Ω1.77~14000Ω
Accuracy0.35%+0.1008S0.35%+630uS0.35%+0.02S0.1%+126uS0.35%+0.176S0.35%+0.0011S0.35%+0.035S0.1%+220uS
Resolution16  bits
Slope
Current Slope Range6-360A/ms360-18000A/ms2-120A/ms120-6000A/ms10.5-630A/ms630-31500A/ms3.5-210A/ms210-10500A/ms
Voltage Slope Range5.0-250V/ms250-2500V/ms8-400V/ms400-4000V/ms5.0-250V/ms250-2500V/ms8-400V/ms400-4000V/ms
Power Slope Range6-360A/ms360-18000A/ms2-120A/ms120-6000A/ms10.5-630A/ms630-31500A/ms3.5-210A/ms210-10500A/ms
Resistance Slope Range6-360A/ms360-18000A/ms2-120A/ms120-6000A/ms10.5-630A/ms630-31500A/ms3.5-210A/ms210-10500A/ms
Accuracy(1±35%)*Set Value
Voltage Measurement
Range0-60V0-600V0-100V0-1000V0-60V0-600V0-100V0-1000V
Accuracy0.05%+0.05%F.S.0.05%+0.05%F.S.0.05%+0.05%F.S.0.05%+0.05%F.S.
Current Measurement
Range0‐36A0‐360A0‐12A0-120A0‐63A0‐630A0‐21A0‐210A
Accuracy0.1%+0.1%F.S.0.1%+0.1%F.S.0.1%+0.1%F.S.0.1%+0.1%F.S.
Power Measurement
Range0-12,000W0-12,000W0-21,000W0-21,000W
Accuracy0.5%+1%F.S.0.5%+1%F.S.0.5%+1%F.S.0.5%+1%F.S.
Transient Measurement
T1&T20.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms
Resolution1us1ms1us1ms1us1ms1us1ms
Accuracy1us+100ppm1ms+100ppm1us+100ppm1ms+100ppm1us+100ppm1ms+100ppm1us+100ppm1ms+100ppm
Dimensions52cm(H)×48cm(W)×64cm(D)116cm(H)×60cm(W)×80cm(D)
Temperature SpecificationsProtection temperature 85°C, operating temperature 0 ~40 °C, full power operating temperature 0 ~25 °C

Product Selection Table:

Input Parameters150V600V1200VHeight
4kWCRIK5004-150-400CRIK5004-600-280CRIK5004-1200-1604U
5kWCRIK5005-150-500CRIK5005-600-350CRIK5005-1200-2004U
6kWCRIK5006-150-600CRIK5006-600-420CRIK5006-1200-2404U
8kWCRIK5008-150-800CRIK5008-600-560CRIK5008-1200-3207U
10kWCRIK5001-150-1000CRIK5001-600-700CRIK5001-1200-4007U
12kWCRIK5002-150-1200CRIK5002-600-840CRIK5002-1200-4807U
18kWCRIK5008-150-1800CRIK5008-600-1260CRIK5008-1200-72014U
24kWCRIK5024-150-2400CRIK5024-600-1680CRIK5024-1200-96014U
30kWCRIK5030-150-3000CRIK5030-600-2100CRIK5030-1200-120022U
36kWCRIK5036-150-3000CRIK5036-600-2520CRIK5036-1200-144022U
42kWCRIK5042-150-3000CRIK5042-600-2940CRIK5042-1200-168022U
48kWCRIK5048-150-3000CRIK5048-600-3000CRIK5048-1200-192032U
54kWCRIK5054-150-3000CRIK5054-600-3000CRIK5054-1200-216032U
60kWCRIK5060-150-3000CRIK5060-600-3000CRIK5060-1200-240032U
72kWCRIK5072-150-3000CRIK5072-600-3000CRIK5072-1200-288039U
700WCRIK5007-150-80CRIK5007-600-60CRIK5007-1200-252U
1200WCRIK5012-150-160CRIK5012-600-120CRIK5012-1200-502U
1500WCRIK5015-150-160CRIK5015-600-120CRIK5015-1200-502U
1800WCRIK5018-150-200CRIK5018-600-150CRIK5018-1200-602U
2250WCRIK5022-150-240CRIK5022-600-180CRIK5022-1200-752U
2400WCRIK5024-150-280CRIK5024-600-210CRIK5024-1200-902U
3000WCRIK5030-150-320CRIK5030-600-240CRIK5030-1200-1002U
Input Power20VFull Current VoltageHeight
400WCRIK5004FZ-20-1500V2U
600WCRIK5006FZ-20-3000V2U
750WCRIK5007FZ-20-1500V2U
1kWCRIK5010FZ-20-3000V4U
1.2kWCRIK5012FZ-20-6000V4U
1.5kWCRIK5015FZ-20-3000V4U
2kWCRIK5020FZ-20-3000V4U
1.8kWCRIK5018FZ-20-9000V6U
2.2kWCRIK5022FZ-20-4500V6U
3kWCRIK5030FZ-20-4500V6U
2.4kWCRIK5030FZ-20-12000V8U
Input Power40VFull Current VoltageHeight
750WCRIK5007F-40-150    0.2V2U
1500WCRIK5015F-40-3000.2V2U
2250WCRIK5022F-40-4500.2V2U
3000WCRIK5030F-40-6000.2V2U
4500WCRIK5045F-40-9000.2V4U
6000WCRIK5060F-40-12000.2V4U
9000WCRIK5090F-40-18000.2V6U
12000WCRIK5120F-40-24000.2V8U
15000WCRIK5150F-40-30000.2V10U
18000WCRIK5180F-40-36000.2V12U
21000WCRIK5210F-40-42000.2V14U

◆ Special specifications can be customized according to customer requirements (power, stepping, size, display, customized model cycle is slightly longer)

Image Name

Related Products

Online Consultation


Please fill in the correct contact information, our customer service staff will contact you as soon as possible!

%{tishi_zhanwei}%