News

IUXPOWER Electronic Technolohy Co;Ltd

What Should EVSE Manufacturers Do After the Release of IEC 63407:2026?

Date:

29 Oct,2026


The publication of IEC 63407:2026 does not mean every EVSE manufacturer must immediately redesign its products. The first step is determining whether a product falls within the standard’s scope.

A practical implementation roadmap includes:

1. Confirm the product boundary

Determine whether the equipment uses an automated connection device, performs conductive DC charging, operates at no more than 1,500 V DC and uses the relevant isolated charging architecture.

2. Build a standards matrix

Map IEC 63407 against IEC 61851-23-1, IEC 61851-23, IEC 61851-24, ISO 15118-20 and IEC 61851-21-2. Separate responsibilities for the interface, electrical system, communication and EMC.

3. Perform a gap analysis

Review connection-state detection, high-voltage interlocking, abnormal shutdown, communication-error handling and test-data traceability.

4. Upgrade the validation platform

The test bench should reproduce vehicle requests, load changes, SOC progression, communication failures, insulation faults and abnormal connector conditions. It should also record voltage, current, power, messages and state transitions.

5. Separate engineering validation from certification

An internal test platform supports design verification, troubleshooting and pre-compliance testing. A formal conformity claim must still be based on the complete standard and the appropriate assessment procedure.

IEC 63407 represents more than an increase in charging power. It advances standardized automated connection. Future competitiveness will increasingly depend on whether charging equipment can establish the connection and complete energy transfer automatically, safely, reliably and repeatedly.

 
 

More News